Is it effective to perform two more prostate biopsies according to prostate-specific antigen level and prostate volume in detecting prostate cancer? Prospective study of 10-core and 12-core prostate biopsy - Abstract

PURPOSE: To evaluate the effectiveness of 2 more core prostate biopsy protocol in detecting the prostate cancer (PCa) by comparing 10-core prostate biopsy with 12-core according to the prostate-specific antigen (PSA) level and the prostate volume.

MATERIALS AND METHODS: A total of 474 men with elevated serum levels of PSA between 2.5 and 20.0 ng/mL, regardless of abnormal finding on digital rectal examination and transrectal ultrasonography, received transrectal ultrasound-guided prostate biopsies. The patients were prospectively randomized to undergo 10-core (group 1, n = 351) or 12-core (group 2, n = 123) biopsy. The PCa detection rates were assessed and compared according to the serum level of PSA and prostate volume.

RESULTS: Of 474 men, 128 (27.0%) were diagnosed with PCa. The PCa detection rates of 10-core and 12-core biopsies were 26.4% and 28.4%, respectively (P = .378). There was no difference in cancer detection rates according to PSA level in both groups. Comparing the cancer detection rates according to the prostate volume (< 40 mL and ≥ 40 mL), the patients with prostate volume ≥ 40 mL showed higher cancer detection rates in 12-core biopsy group (26.9%) compared with 10-core biopsy group (16.4%) (P < .05).

CONCLUSION: The overall cancer detection rates showed no differences in both groups. But the 12-core biopsy was a more efficient method in men with a prostate volume of ≥ 40 mL, compared to the 10-core biopsy.

Written by:
Yoon BI, Shin TS, Cho HJ, Hong SH, Lee JY, Hwang TK, Kim SW   Are you the author?
Department of Urology, The Catholic University of Korea, College of Medicine, Seoul, Korea

Reference: Urol J. 2012 Spring;9(2):491-7

PubMed Abstract
PMID: 22641493