Comparative diagnostic performance of contrast-enhanced ultrasound and dynamic contrast-enhanced magnetic resonance imaging for differentiating clear cell and non-clear cell renal cell carcinoma.

To compare the diagnostic efficiency of contrast-enhanced ultrasound (CEUS) with that of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) for the differential diagnosis of clear and non-clear cell renal cell carcinoma, as confirmed by subsequent pathology.

A total of 181 patients with 184 renal lesions diagnosed by both CEUS and DCE-MRI were enrolled in the study, including 136 clear cell renal cell carcinoma (ccRCC) and 48 non-clear cell renal cell carcinoma (non-ccRCC) tumors. All lesions were confirmed by histopathologic diagnosis after surgical resection. Interobserver agreement was estimated using a weighted kappa statistic. Diagnostic efficiency in evaluating ccRCC and non-ccRCC was compared between CEUS and DCE-MRI.

The weighted kappa value for interobserver agreement was 0.746 to 0.884 for CEUS diagnosis and 0.764 to 0.895 for DCE-MRI diagnosis. Good diagnostic performance in differential diagnosis of ccRCC and non-ccRCC was displayed by both CEUS and DCE-MRI: sensitivity was 89.7% and 91.9%, respectively; specificity was 77.1% and 68.8%, respectively; and area under the receiver operating curve was 0.834 and 0.803, respectively. No statistically significant differences were present between the two methods (p = 0.54).

Both CEUS and DCE-MRI imaging are effective for the differential diagnosis of ccRCC and non-ccRCC. Thus, CEUS could be an alternative to DCE-MRI as a first test for patients at risk of renal cancer, particularly where DCE-MRI cannot be carried out.

• CEUS and DCE-MRI features can help differentiate ccRCC and non-ccRCC. • The differential diagnosis of ccRCC and non-ccRCC by CEUS is comparable to that of DCE-MRI. • Interobserver agreement is generally high using CEUS and DCE-MRI.

European radiology. 2023 Feb 01 [Epub ahead of print]

Ping Zhao, Jianing Zhu, Lanke Wang, Nan Li, Xinghua Zhang, Jinfeng Li, Yukun Luo, Qiuyang Li

School of Medicine, Nankai University, Tianjin, 300071, China., Department of Ultrasound, First Medical Center, Chinese PLA General Hospital, Beijing, 100853, China., Department of Radiology, First Medical Center, Chinese PLA General Hospital, Beijing, 100853, China., School of Medicine, Nankai University, Tianjin, 300071, China. ., Department of Ultrasound, First Medical Center, Chinese PLA General Hospital, Beijing, 100853, China. .